<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Electro-Optics Archives - Axis Photonique Inc.</title>
	<atom:link href="https://www.axis-photon.com/camera/electro-optics/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.axis-photon.com/camera/electro-optics/</link>
	<description>Ultrafast Streak Cameras Systems</description>
	<lastBuildDate>Tue, 30 Mar 2021 23:39:37 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://www.axis-photon.com/wp-content/uploads/2017/05/cropped-axis-logo_seul_ombrage-32x32.png</url>
	<title>Electro-Optics Archives - Axis Photonique Inc.</title>
	<link>https://www.axis-photon.com/camera/electro-optics/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>AXIS-MIPP Mid-IR Pulse Picker</title>
		<link>https://www.axis-photon.com/streak-camera/axis-mipp-mid-ir-pulse-picker/</link>
					<comments>https://www.axis-photon.com/streak-camera/axis-mipp-mid-ir-pulse-picker/#respond</comments>
		
		<dc:creator><![CDATA[CHRISTIAN]]></dc:creator>
		<pubDate>Tue, 30 Mar 2021 23:31:29 +0000</pubDate>
				<guid isPermaLink="false">https://www.axis-photon.com/?post_type=avada_portfolio&#038;p=3205</guid>

					<description><![CDATA[<p>AXIS-MIPP Mid-IR Pulse Picker        Main Features: Developped for mid-IR (l = 2.8 µm) Based on a RTP crystal (2 mm x 2 mm x 20 mm)  Extinction ratio: &gt; 200:1 Uses photodiode signal from laser oscillator (50 MHz) Pulse picking frequency: 0.8 to 67 kHz</p>
<p>L’article <a href="https://www.axis-photon.com/streak-camera/axis-mipp-mid-ir-pulse-picker/">AXIS-MIPP Mid-IR Pulse Picker</a> est apparu en premier sur <a href="https://www.axis-photon.com">Axis Photonique Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><div class="fusion-fullwidth fullwidth-box fusion-builder-row-1 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-background-position:left top;--awb-border-sizes-top:0px;--awb-border-sizes-bottom:0px;--awb-border-sizes-left:0px;--awb-border-sizes-right:0px;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:15px;--awb-padding-bottom:7px;--awb-background-color:#bb003c;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-0 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-1"><h2 style="font-weight: 300; text-align: center;"><span style="color: #ffffff;">AXIS-MIPP Mid-IR Pulse Picker</span></h2>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-2 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap" style="max-width:1216.8px;margin-left: calc(-4% / 2 );margin-right: calc(-4% / 2 );"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-flex-column" style="--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column"><div class="fusion-separator fusion-full-width-sep" style="align-self: center;margin-left: auto;margin-right: auto;margin-top:5px;width:100%;"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-3 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:20px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-first" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-2"><p><strong>Main Features:</strong></p>
</div><ul style="--awb-iconcolor:#bb003c;--awb-line-height:23.8px;--awb-icon-width:23.8px;--awb-icon-height:23.8px;--awb-icon-margin:9.8px;--awb-content-margin:33.6px;" class="fusion-checklist fusion-checklist-1 fusion-checklist-default type-icons"><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">Developped for mid-IR (<span style="font-family: symbol;">l </span> = 2.8 µm)</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa-check fas" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Based on a RTP crystal (2 mm x 2 mm x 20 mm)</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Extinction ratio: &gt; 200:1</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">Uses photodiode signal from laser oscillator (50 MHz)</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Pulse picking frequency:    0.8 to 67 kHz</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Internal jitter-free delay generator ( 25 ps steps)</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>2 programmable output channels at picking frequency for applications.</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Control via USB interface</p>
</div></li></ul><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-1 hover-type-none"><img fetchpriority="high" decoding="async" width="334" height="245" alt="AXIS-MIPP Mid-IR Pulse Picker" title="axis-mipp-mid-ir-pulse-picker" src="https://www.axis-photon.com/wp-content/uploads/2021/03/axis-mipp-mid-ir-pulse-picker.png" class="img-responsive wp-image-3204" srcset="https://www.axis-photon.com/wp-content/uploads/2021/03/axis-mipp-mid-ir-pulse-picker-200x147.png 200w, https://www.axis-photon.com/wp-content/uploads/2021/03/axis-mipp-mid-ir-pulse-picker.png 334w" sizes="(max-width: 800px) 100vw, 334px" /></span></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:0px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-3 fusion_builder_column_1_2 1_2 fusion-one-half fusion-column-last" style="--awb-bg-size:cover;width:50%;width:calc(50% - ( ( 4% ) * 0.5 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-3"><p><strong>Measurements @ 2.8 µm</strong></p>
<p>The fiber laser generates femtosecond pulses @ 2.8 microns at a rate of 45 MHz. </p>
<p>The pulse picker frequency is 67 kHz.</p>
</div><div class="fusion-image-element in-legacy-container" style="--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><span class=" fusion-imageframe imageframe-none imageframe-2 hover-type-none"><img decoding="async" width="350" height="171" alt="AXIS-MIPP Mid-IR Pulse Picker Measurements @ 2.8 microns" title="mipp_pulse_picker_measurements" src="https://www.axis-photon.com/wp-content/uploads/2021/03/mipp_pulse_picker_measurements.png" class="img-responsive wp-image-3209" srcset="https://www.axis-photon.com/wp-content/uploads/2021/03/mipp_pulse_picker_measurements-200x98.png 200w, https://www.axis-photon.com/wp-content/uploads/2021/03/mipp_pulse_picker_measurements.png 350w" sizes="(max-width: 800px) 100vw, 350px" /></span></div><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;margin-bottom:10px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-4"><p>The <span style="color: #ff0000;">red</span> arrows represent the oscillator pulses.</p>
<p>The <span style="color: #ffcc00;">yellow</span> trace is the electro-optical window,</p>
<p>The <span style="color: #339966;">green</span> signal is the selected femtosecond pulse (seen by a slow photodiode) .</p>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-4 fusion-flex-container nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row fusion-flex-align-items-flex-start fusion-flex-content-wrap" style="max-width:1216.8px;margin-left: calc(-4% / 2 );margin-right: calc(-4% / 2 );"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-4 fusion_builder_column_1_1 1_1 fusion-flex-column" style="--awb-bg-size:cover;--awb-width-large:100%;--awb-margin-top-large:0px;--awb-spacing-right-large:1.92%;--awb-margin-bottom-large:0px;--awb-spacing-left-large:1.92%;--awb-width-medium:100%;--awb-order-medium:0;--awb-spacing-right-medium:1.92%;--awb-spacing-left-medium:1.92%;--awb-width-small:100%;--awb-order-small:0;--awb-spacing-right-small:1.92%;--awb-spacing-left-small:1.92%;"><div class="fusion-column-wrapper fusion-column-has-shadow fusion-flex-justify-content-flex-start fusion-content-layout-column"><div class="fusion-separator fusion-full-width-sep" style="align-self: center;margin-left: auto;margin-right: auto;margin-top:5px;width:100%;"></div></div></div></div></div></p>
<p>L’article <a href="https://www.axis-photon.com/streak-camera/axis-mipp-mid-ir-pulse-picker/">AXIS-MIPP Mid-IR Pulse Picker</a> est apparu en premier sur <a href="https://www.axis-photon.com">Axis Photonique Inc.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.axis-photon.com/streak-camera/axis-mipp-mid-ir-pulse-picker/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Femtosecond Laser Phase Scanner for SHG Microscopy</title>
		<link>https://www.axis-photon.com/streak-camera/femtosecond-laser-phase-scanner-for-shg-microscopy/</link>
					<comments>https://www.axis-photon.com/streak-camera/femtosecond-laser-phase-scanner-for-shg-microscopy/#respond</comments>
		
		<dc:creator><![CDATA[CHRISTIAN]]></dc:creator>
		<pubDate>Thu, 19 Mar 2020 23:31:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.axis-photon.com/?post_type=avada_portfolio&#038;p=2866</guid>

					<description><![CDATA[<p>Femtosecond Laser Phase Scanner for SHG Microscopy     Researchers from Institut National de la Recherche Scientifique and Axis Photonique have developed a new Interferometric Second Harmonic Generation (ISHG) Microscope that combines interferometry and SHG microscopy techniques. By recording the SHG signal as well as its phase, this laser microscope allows a</p>
<p>L’article <a href="https://www.axis-photon.com/streak-camera/femtosecond-laser-phase-scanner-for-shg-microscopy/">Femtosecond Laser Phase Scanner for SHG Microscopy</a> est apparu en premier sur <a href="https://www.axis-photon.com">Axis Photonique Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><div class="fusion-fullwidth fullwidth-box fusion-builder-row-5 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-background-position:left top;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:15px;--awb-padding-bottom:7px;--awb-background-color:#bb003c;--awb-border-sizes-top:0px;--awb-border-sizes-bottom:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-5 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-5"><h2 style="font-weight: 300; text-align: center;"><span style="color: #ffffff;">Femtosecond Laser Phase Scanner for SHG Microscopy</span></h2>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-6 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:20px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-6 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-first" style="--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-6"><p>Researchers from Institut National de la Recherche Scientifique and Axis Photonique have developed a new Interferometric Second Harmonic Generation (ISHG) Microscope that combines interferometry and SHG microscopy techniques. By recording the SHG signal as well as its phase, this laser microscope allows a better imaging accuracy when studying biological tissues, like cartilage and muscular tissues.</p>
<p>The microscope scans the phase within each pixel of the sample, using a kHz CPA laser and an ultrafast electro-optical phase scanner from Axis Photonique.</p>
</div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-7 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-last" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-3 hover-type-none"><a href="https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner_hardware-300x177.png" class="fusion-lightbox" data-rel="iLightbox[c5c60ac26484b2d2748]" data-title="axis-fs-laser-phase-scanner_hardware" title="axis-fs-laser-phase-scanner_hardware"><img decoding="async" width="300" height="177" alt="AXIS-TRS: ULTRAFAST TIME-RESOLVED SPECTROMETER" src="https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner_hardware-300x177.png" class="img-responsive wp-image-2868" srcset="https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner_hardware-200x118.png 200w, https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner_hardware-400x236.png 400w, https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner_hardware-600x354.png 600w, https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner_hardware-800x472.png 800w, https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner_hardware-1200x709.png 1200w, https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner_hardware.png 1236w" sizes="(max-width: 800px) 100vw, 400px" /></a></span></div></div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-7 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:20px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-8 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-7"><p>In conventional laser-scanning microscopy, images are formed by acquiring the signal from pixel to pixel. Using the new single-scan interferometric SHG microscope, one can obtain more than one order of magnitude reduction in acquisition time by scanning the phase within each pixel, to characterize the relative polarity of various samples. Using the AXIS Femtosecond Laser Phase Scanner, the phase-shift patterns required for interferometry can be applied at each pixel during the scanning of the sample, allowing single-scan I-SHG (1S-ISHG) measurements. Requiring exposure times comparable to standard SHG intensity images, the additional phase information of the signal can thus be retrieved in parallel to its amplitude at the time-scale of seconds. Moreover, slower modulations can be used to enhance the precision of the phase measurement, without any spatial or temporal shift between interferograms, in contrast to conventional frame phase-shifting I-SHG (standard I-SHG).</p>
</div><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-4 hover-type-none"><img decoding="async" width="507" height="233" title="axis-fs-laser-phase-scanner" src="https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner.png" alt class="img-responsive wp-image-2867" srcset="https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner-200x92.png 200w, https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner-400x184.png 400w, https://www.axis-photon.com/wp-content/uploads/2020/03/axis-fs-laser-phase-scanner.png 507w" sizes="(max-width: 800px) 100vw, 507px" /></span></div></div><div class="fusion-text fusion-text-8"><p style="text-align: center;"><strong>&#8220;Single-scan interferometric second harmonic generation microscopy using a kHz phase-scanner&#8221;</strong><br />
M. Pinsard, L.P. Belley, J.M. Piau, C.Y. Côté, H. Ibrahim, F. Légaré,<br />
<a href="https://doi.org/10.1364/OE.27.038435" target="_blank" rel="noopener noreferrer">Opt. Express 27, 38435-38450 (2019).</a></p>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-8 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-9 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:50px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-clearfix"></div></div></div></div></div></p>
<p>L’article <a href="https://www.axis-photon.com/streak-camera/femtosecond-laser-phase-scanner-for-shg-microscopy/">Femtosecond Laser Phase Scanner for SHG Microscopy</a> est apparu en premier sur <a href="https://www.axis-photon.com">Axis Photonique Inc.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.axis-photon.com/streak-camera/femtosecond-laser-phase-scanner-for-shg-microscopy/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>AXIS Streak Camera Synchronization Unit</title>
		<link>https://www.axis-photon.com/streak-camera/axis-streak-camera-synchronization-unit/</link>
					<comments>https://www.axis-photon.com/streak-camera/axis-streak-camera-synchronization-unit/#respond</comments>
		
		<dc:creator><![CDATA[CHRISTIAN]]></dc:creator>
		<pubDate>Thu, 25 May 2017 03:03:53 +0000</pubDate>
				<guid isPermaLink="false">http://www.axis-photon.com/?post_type=avada_portfolio&#038;p=1973</guid>

					<description><![CDATA[<p>AXIS Streak Camera Synchronization Unit     Custom Synchronization unit for complex experiments involving femtosecond laser chain and multiple beams (Hz to MHz).   Some ultrafast laser chains are synchronized with a masterclock having a jitter of 100s of picoseconds. To operate an AXIS ultrafast streak camera, one needs a trigger signal with</p>
<p>L’article <a href="https://www.axis-photon.com/streak-camera/axis-streak-camera-synchronization-unit/">AXIS Streak Camera Synchronization Unit</a> est apparu en premier sur <a href="https://www.axis-photon.com">Axis Photonique Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><div class="fusion-fullwidth fullwidth-box fusion-builder-row-9 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-background-position:left top;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:15px;--awb-padding-bottom:7px;--awb-background-color:#bb003c;--awb-border-sizes-top:0px;--awb-border-sizes-bottom:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-10 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-9"><h2 style="font-weight: 300; text-align: center;"><span style="color: #ffffff;">AXIS Streak Camera Synchronization Unit</span></h2>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-10 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:20px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-11 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-first" style="--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-10"><p>Custom Synchronization unit for complex experiments involving femtosecond laser chain and multiple beams (Hz to MHz).</p>
</div><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-5 hover-type-none"><a href="http://www.axis-photon.com/wp-content/uploads/2017/05/axis-streak-cam-sync-unit.jpg" class="fusion-lightbox" data-rel="iLightbox[c095de996505d7c8c95]" data-caption="Axis Streak Camera Synchronization Unit" data-title="axis-streak-cam-sync-unit" title="axis-streak-cam-sync-unit"><img decoding="async" width="294" height="148" alt="AXIS-TRS: ULTRAFAST TIME-RESOLVED SPECTROMETER" src="http://www.axis-photon.com/wp-content/uploads/2017/05/axis-streak-cam-sync-unit.jpg" class="img-responsive wp-image-1974" srcset="https://www.axis-photon.com/wp-content/uploads/2017/05/axis-streak-cam-sync-unit-200x101.jpg 200w, https://www.axis-photon.com/wp-content/uploads/2017/05/axis-streak-cam-sync-unit.jpg 294w" sizes="(max-width: 800px) 100vw, 294px" /></a></span></div></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-12 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-last" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-11"><p>Some ultrafast laser chains are synchronized with a masterclock having a jitter of 100s of picoseconds. To operate an AXIS ultrafast streak camera, one needs a trigger signal with a jitter lower than 15 ps.</p>
<p>The AXIS synchronization unit solves this problem by generating triggers signals from 80MHz optical pulse of the oscillator. It also acts as jitter free delay generator which can control the delay between 0 and 32 ns with steps of 25 ps.</p>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-11 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-13 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:50px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-clearfix"></div></div></div></div></div></p>
<p>L’article <a href="https://www.axis-photon.com/streak-camera/axis-streak-camera-synchronization-unit/">AXIS Streak Camera Synchronization Unit</a> est apparu en premier sur <a href="https://www.axis-photon.com">Axis Photonique Inc.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.axis-photon.com/streak-camera/axis-streak-camera-synchronization-unit/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>Ultrafast Laser Pulse Shaping</title>
		<link>https://www.axis-photon.com/streak-camera/ultrafast-laser-pulse-shaping/</link>
					<comments>https://www.axis-photon.com/streak-camera/ultrafast-laser-pulse-shaping/#respond</comments>
		
		<dc:creator><![CDATA[CHRISTIAN]]></dc:creator>
		<pubDate>Thu, 25 May 2017 01:40:41 +0000</pubDate>
				<guid isPermaLink="false">http://www.axis-photon.com/?post_type=avada_portfolio&#038;p=1947</guid>

					<description><![CDATA[<p>Ultrafast Laser Pulse Shaping: Custom Pockels Cells      Pockels Cells Systems:  Based on RTP or KDP crystals  Repetition rates up to 1 MHz  Extinction ratio: 20dB (30dB available)  Jitter less than 100ps  Full customized synchronization available  Twin-Peak configuration available    Applications:</p>
<p>L’article <a href="https://www.axis-photon.com/streak-camera/ultrafast-laser-pulse-shaping/">Ultrafast Laser Pulse Shaping</a> est apparu en premier sur <a href="https://www.axis-photon.com">Axis Photonique Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><div class="fusion-fullwidth fullwidth-box fusion-builder-row-12 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-background-position:left top;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:15px;--awb-padding-bottom:7px;--awb-background-color:#bb003c;--awb-border-sizes-top:0px;--awb-border-sizes-bottom:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-14 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-12"><h2 style="font-weight: 300; text-align: center;"><span style="color: #ffffff;">Ultrafast Laser Pulse Shaping: Custom Pockels Cells</span></h2>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-13 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:20px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-15 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-first" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:50px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-13"><p>Pockels Cells Systems:</p>
</div><ul style="--awb-iconcolor:#bb003c;--awb-line-height:23.8px;--awb-icon-width:23.8px;--awb-icon-height:23.8px;--awb-icon-margin:9.8px;--awb-content-margin:33.6px;" class="fusion-checklist fusion-checklist-2 fusion-checklist-default type-icons"><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa-check fas" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Based on RTP or KDP crystals</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Repetition rates up to 1 MHz</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Extinction ratio: 20dB (30dB available)</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Jitter less than 100ps</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Full customized synchronization available</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon awb-icon-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Twin-Peak configuration available</p>
</div></li></ul><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:50px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-text fusion-text-14"><p>Applications:</p>
</div><ul style="--awb-iconcolor:#bb003c;--awb-line-height:23.8px;--awb-icon-width:23.8px;--awb-icon-height:23.8px;--awb-icon-margin:9.8px;--awb-content-margin:33.6px;" class="fusion-checklist fusion-checklist-3 fusion-checklist-default type-icons"><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Pulse picking from laser oscillator up to 125 MHz</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Slicing into long pulses</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Contrast enhancement on femtosecond laser chain</p>
</div></li></ul><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-16 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-last" style="--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-content-boxes content-boxes columns row fusion-columns-1 fusion-columns-total-2 fusion-content-boxes-1 content-boxes-icon-with-title content-left" style="--awb-hover-accent-color:#c0263e;--awb-circle-hover-accent-color:#c0263e;--awb-item-margin-bottom:40px;" data-animationOffset="top-into-view"><div style="--awb-backgroundcolor:rgba(255,255,255,0);" class="fusion-column content-box-column content-box-column content-box-column-1 col-lg-12 col-md-12 col-sm-12 fusion-content-box-hover content-box-column-last-in-row"><div class="col content-box-wrapper content-wrapper link-area-link-icon icon-hover-animation-pulsate" data-animationOffset="top-into-view"><div class="fusion-clearfix"></div><div class="content-container">
<div id="attachment_1949" style="width: 369px" class="wp-caption alignnone"><img decoding="async" aria-describedby="caption-attachment-1949" class="wp-image-1949 size-full" src="http://www.axis-photon.com/wp-content/uploads/2017/05/axis-pulse-selector-for-regen.jpg" alt="Axis Pulse selector for CPA Renenerative Amplifier" width="359" height="181" /><p id="caption-attachment-1949" class="wp-caption-text">Pulse selector for CPA Renenerative Amplifier</p></div>
</div></div></div><div style="--awb-backgroundcolor:rgba(255,255,255,0);" class="fusion-column content-box-column content-box-column content-box-column-2 col-lg-12 col-md-12 col-sm-12 fusion-content-box-hover content-box-column-last content-box-column-last-in-row"><div class="col content-box-wrapper content-wrapper link-area-link-icon icon-hover-animation-pulsate" data-animationOffset="top-into-view"><div class="fusion-clearfix"></div><div class="content-container">
<div id="attachment_1948" style="width: 385px" class="wp-caption alignnone"><img decoding="async" aria-describedby="caption-attachment-1948" class="size-full wp-image-1948" src="http://www.axis-photon.com/wp-content/uploads/2017/05/axis-pulse-picker.jpg" alt="Pulse Picker for femtosecond laser" width="375" height="250" srcset="https://www.axis-photon.com/wp-content/uploads/2017/05/axis-pulse-picker-200x133.jpg 200w, https://www.axis-photon.com/wp-content/uploads/2017/05/axis-pulse-picker-300x200.jpg 300w, https://www.axis-photon.com/wp-content/uploads/2017/05/axis-pulse-picker.jpg 368w" sizes="(max-width: 375px) 100vw, 375px" /><p id="caption-attachment-1948" class="wp-caption-text">Pulse Picker for femtosecond laser</p></div>
</div></div></div><div class="fusion-clearfix"></div></div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-14 hundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-17 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:20px;margin-bottom:20px;width:100%;"><div class="fusion-separator-border sep-single sep-solid" style="--awb-height:20px;--awb-amount:20px;--awb-sep-color:#bb003c;border-color:#bb003c;border-top-width:4px;"></div></div><div class="fusion-sep-clear"></div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-15 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-18 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-content-boxes content-boxes columns row fusion-columns-2 fusion-columns-total-2 fusion-content-boxes-2 content-boxes-icon-with-title content-left" style="--awb-hover-accent-color:#c0263e;--awb-circle-hover-accent-color:#c0263e;" data-animationOffset="top-into-view"><div style="--awb-backgroundcolor:rgba(255,255,255,0);" class="fusion-column content-box-column content-box-column content-box-column-1 col-lg-6 col-md-6 col-sm-6 fusion-content-box-hover content-box-column-first-in-row"><div class="col content-box-wrapper content-wrapper link-area-link-icon icon-hover-animation-pulsate" data-animationOffset="top-into-view"><div class="fusion-clearfix"></div><div class="content-container">
<p>We also repair <strong>MEDOX Pockels Cell Drivers</strong>. Please <a title="Contact Information and Enquiry Form" href="http://www.axis-photon.com/contact-canada/">contact us</a> for details.</p>
</div></div></div><div style="--awb-backgroundcolor:rgba(255,255,255,0);" class="fusion-column content-box-column content-box-column content-box-column-2 col-lg-6 col-md-6 col-sm-6 fusion-content-box-hover content-box-column-last content-box-column-last-in-row"><div class="col content-box-wrapper content-wrapper link-area-link-icon icon-hover-animation-pulsate" data-animationOffset="top-into-view"><div class="fusion-clearfix"></div><div class="content-container">
<p><img decoding="async" class="alignnone size-full wp-image-1964" src="http://www.axis-photon.com/wp-content/uploads/2017/05/medox-pockels-cell-driver.jpg" alt="Medox Pockels Cell Driver" width="208" height="150" srcset="https://www.axis-photon.com/wp-content/uploads/2017/05/medox-pockels-cell-driver-200x144.jpg 200w, https://www.axis-photon.com/wp-content/uploads/2017/05/medox-pockels-cell-driver.jpg 208w" sizes="(max-width: 208px) 100vw, 208px" /></p>
</div></div></div><div class="fusion-clearfix"></div></div><div class="fusion-clearfix"></div></div></div></div></div></p>
<p>L’article <a href="https://www.axis-photon.com/streak-camera/ultrafast-laser-pulse-shaping/">Ultrafast Laser Pulse Shaping</a> est apparu en premier sur <a href="https://www.axis-photon.com">Axis Photonique Inc.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.axis-photon.com/streak-camera/ultrafast-laser-pulse-shaping/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>AXIS-PHVS: Precision High Voltage Supply</title>
		<link>https://www.axis-photon.com/streak-camera/axis-phvs-precision-high-voltage-supply/</link>
					<comments>https://www.axis-photon.com/streak-camera/axis-phvs-precision-high-voltage-supply/#respond</comments>
		
		<dc:creator><![CDATA[CHRISTIAN]]></dc:creator>
		<pubDate>Thu, 25 May 2017 01:01:30 +0000</pubDate>
				<guid isPermaLink="false">http://www.axis-photon.com/?post_type=avada_portfolio&#038;p=1940</guid>

					<description><![CDATA[<p>AXIS-PHVS: Precision High Voltage Supply     Custom High voltage supply with up to 8 channels, each delivering a programmable voltage up to 1kV, 2kV, 4kV, 6kV, 10kV or 15kV. Remote control with fiber communication is available.  Portable system with:  2 ppm stability at constant temperature  15 ppm voltage variation</p>
<p>L’article <a href="https://www.axis-photon.com/streak-camera/axis-phvs-precision-high-voltage-supply/">AXIS-PHVS: Precision High Voltage Supply</a> est apparu en premier sur <a href="https://www.axis-photon.com">Axis Photonique Inc.</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p><div class="fusion-fullwidth fullwidth-box fusion-builder-row-16 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-background-position:left top;--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-padding-top:15px;--awb-padding-bottom:7px;--awb-background-color:#bb003c;--awb-border-sizes-top:0px;--awb-border-sizes-bottom:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-19 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-15"><h2 style="font-weight: 300; text-align: center;"><span style="color: #ffffff;">AXIS-PHVS: Precision High Voltage Supply</span></h2>
</div><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-17 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-margin-top:20px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-20 fusion_builder_column_2_3 2_3 fusion-two-third fusion-column-first" style="--awb-bg-size:cover;width:66.666666666667%;width:calc(66.666666666667% - ( ( 4% ) * 0.66666666666667 ) );margin-right: 4%;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-16"><p>Custom High voltage supply with up to 8 channels, each delivering a programmable voltage up to 1kV, 2kV, 4kV, 6kV, 10kV or 15kV. Remote control with fiber communication is available.</p>
</div><div class="fusion-image-element fusion-image-align-center in-legacy-container" style="text-align:center;--awb-caption-title-font-family:var(--h2_typography-font-family);--awb-caption-title-font-weight:var(--h2_typography-font-weight);--awb-caption-title-font-style:var(--h2_typography-font-style);--awb-caption-title-size:var(--h2_typography-font-size);--awb-caption-title-transform:var(--h2_typography-text-transform);--awb-caption-title-line-height:var(--h2_typography-line-height);--awb-caption-title-letter-spacing:var(--h2_typography-letter-spacing);"><div class="imageframe-align-center"><span class=" fusion-imageframe imageframe-none imageframe-6 hover-type-none"><a href="http://www.axis-photon.com/wp-content/uploads/2017/05/axis-phvs-precision-hv-supply.jpg" class="fusion-lightbox" data-rel="iLightbox[f01deac50afb1a5855a]" data-title="axis-phvs-precision-hv-supply" title="axis-phvs-precision-hv-supply"><img decoding="async" width="375" height="245" alt="AXIS-TRS: ULTRAFAST TIME-RESOLVED SPECTROMETER" src="http://www.axis-photon.com/wp-content/uploads/2017/05/axis-phvs-precision-hv-supply.jpg" class="img-responsive wp-image-1943" srcset="https://www.axis-photon.com/wp-content/uploads/2017/05/axis-phvs-precision-hv-supply-200x131.jpg 200w, https://www.axis-photon.com/wp-content/uploads/2017/05/axis-phvs-precision-hv-supply.jpg 375w" sizes="(max-width: 800px) 100vw, 375px" /></a></span></div></div><div class="fusion-clearfix"></div></div></div><div class="fusion-layout-column fusion_builder_column fusion-builder-column-21 fusion_builder_column_1_3 1_3 fusion-one-third fusion-column-last" style="--awb-bg-size:cover;width:33.333333333333%;width:calc(33.333333333333% - ( ( 4% ) * 0.33333333333333 ) );"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-text fusion-text-17"><p><strong>Portable system with:</strong></p>
</div><ul style="--awb-iconcolor:#bb003c;--awb-line-height:23.8px;--awb-icon-width:23.8px;--awb-icon-height:23.8px;--awb-icon-margin:9.8px;--awb-content-margin:33.6px;" class="fusion-checklist fusion-checklist-4 fusion-checklist-default type-icons"><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>2 ppm stability at constant temperature</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>15 ppm voltage variation per °C</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>4W maximum power per channel</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Programmable from the keypad/display interface</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>USB connectivity to PC for remote control</p>
</div></li><li class="fusion-li-item" style=""><span class="icon-wrapper circle-no"><i class="fusion-li-icon fa fa-check" aria-hidden="true"></i></span><div class="fusion-li-item-content">
<p>Remote control with fiber communication is available.</p>
</div></li></ul><div class="fusion-clearfix"></div></div></div></div></div><div class="fusion-fullwidth fullwidth-box fusion-builder-row-18 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling" style="--awb-border-radius-top-left:0px;--awb-border-radius-top-right:0px;--awb-border-radius-bottom-right:0px;--awb-border-radius-bottom-left:0px;--awb-flex-wrap:wrap;" ><div class="fusion-builder-row fusion-row"><div class="fusion-layout-column fusion_builder_column fusion-builder-column-22 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last" style="--awb-bg-size:cover;"><div class="fusion-column-wrapper fusion-flex-column-wrapper-legacy"><div class="fusion-sep-clear"></div><div class="fusion-separator fusion-full-width-sep" style="margin-left: auto;margin-right: auto;margin-top:50px;width:100%;"></div><div class="fusion-sep-clear"></div><div class="fusion-clearfix"></div></div></div></div></div></p>
<p>L’article <a href="https://www.axis-photon.com/streak-camera/axis-phvs-precision-high-voltage-supply/">AXIS-PHVS: Precision High Voltage Supply</a> est apparu en premier sur <a href="https://www.axis-photon.com">Axis Photonique Inc.</a>.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://www.axis-photon.com/streak-camera/axis-phvs-precision-high-voltage-supply/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
